MakeModel Ch.SymptomProblem SolutionSolutionBy:
MitsubishiEuro 6 CT2146TX
Dead - no line driveCarbonised glue around fop chip had caused corrosion of earth track to line gen cct
MitsubishiEuro 6 CT2145BM
No colourLO601 bandpass transformer
MitsubishiEuro 6
No soundCheck for 12v pin 1 & 15.8v at pin 9 of IC361 AN5265 audio o/p chip. If no 15.8v, check C363 1000µ 25v, C915 470µ 25v, R912 0R82 ½w fusible. D911 BYW95B o/c. If no 12v check R368 & R371 100R ½w & zener D362. Also check Q302 JC501QR or IC101 M51496P
MitsubishiEuro 6
No colIC252 TDA3565 running hot and faulty
MitsubishiEuro 6
Int shutdown & poor response to R/C & OSD corruptedC960 dry joints
MitsubishiEuro 6
Int patterningC920 470µ 25v
MitsubishiEuro 6
Dead with squeals/c across lop traced to Loptx s/c between pins 1 (HT) & Chassis pin 7 ; LOPTx 334B08109 = HR7685 £13.25 CPC